Saturday, September 28, 2024

T-216 600A portable contact resistance test set

The risk of overheating is becoming more serious due to the fact that today's distribution networks have to carry heavier loads. Checking contact resistances at regular intervals detects faults before they cause overheating. T-216 600A Contact Resistance Test Set are used to measure contact resistances in high voltage breakers, disconnecting switches (isolators), knife-contact fuses, bus joints, line joints etc.

T-216 contact resistance tester adopts the top open structure or vehicle mounted horizontal chassis. It has that vantage: more small volume, more light weight, more strong functions, and the simple operation. It designed for field tester design. The high output voltage is 10V. Display is 160*128 large LCD screen. Test current optionally, test time can be set, test process dynamic tips, suitable for different working environment. It can save 200 test record, the records can be printed and uploaded to the computer.

Test range

0-20000.0μΩ (100Amp)

0-10000.0μΩ (200Amp)

0-6000.0μΩ (300A)

0-5000.0μΩ (400A)

0-4000.0μΩ (500A)

0-3000.0μΩ (600A) 



Sunday, September 22, 2024

T-218 PORTABLE FULLY AUTOMATIC TRANSFORMER DEMAGNETIZER

The T-218 is a fully automatic transformer demagnetization tester which performs three-phase transformer and single-phase and three-phase power transformers demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. T-218 provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. The principle of the option is to apply a constant current of alternate polarities to the transformer winding, as per the IEEE 0062 1995 standard.

T-218 has a built-in proprietary algorithm for calculating remanent magnetism after the demagnetization. The instrument measures initial flux before demagnetization, maximum flux during demagnetization, and remanent flux after demagnetization. This feature provides useful information about the state of magnetic core after the demagnetization, and assures user that demagnetization process is successful. it enables safe and efficient power transformer demagnetization.

FEATURES

■ Easy to operate;

■ Demagnetize faster;

■ 0.38KV-800KV transformer;

■ 7 inch touch TFT color LCD;

■ Designed for rugged field use;

■ High power, with 8m test cable;

■ Auto test or manual test optional;

■ Demagnetize current 5A, 1A, 200mA;

■ Suite for 3 phase & 1 phase transformer;

■ Portable and lightweight, weight only 5kg;

APPLICATION

■ Universities;

■ Power plant;

■ Research institutes;

■ Electrical testing center;

■ Transformer manufacturers;

■ Voltage transformer factory;

■ Railway electrical department;

■ Electricity power bureau & power company;

■ Power engineering commissioning company;

■ Electrical Department of industrial and mining enterprises;


Tuesday, September 17, 2024

GF211B MULTI-FUNCTION DOUBLE CLAMP DIGITAL PHASE ANGLE METER

GF211B multi-function double clamp digital phase angle meter is a multi-functional portable instrument. It can measure not only alternating voltage, but also alternating current. Its important function is to measure phase angle between two voltages, between two current or between voltage and current. The current signal is obtained by the clamp current transformer without cutting off current wire. It can discern inductive circuit and capacitive circuit; directly read differential protection phase among every unit of CT; check connection of transformer; measure three way voltage phase sequence; check whether the meter connection is right or not; evaluate the running speed of electric kWh meter. It has high resolution of current, so can be used as a leakage current meter. It is an ideal choice for electric power bureau, factories, mine, petroleum-chemistry enterprises, metallurgy factories and so on.

FEATURES

■ Operational simple;

■ Handheld designed;

■ As a power meter on site;

■ Discern inductive circuit and capacitive circuit;

■ Check connection of transformer automatically;

■ Measure two channel voltage phase sequence;

■ Evaluating the running speed of electric kWh meter;

■ Checking whether the meter connection is right or not;

■ High resolution of current, used as a leakage current meter;

■ Directly read differential protection phase among every unit of CT;

■ Current signal is obtained by the clamp current transformer on line directly;

■ Measure phase angle between two channel U, between two channel I or between U & I;

■ Measure alternating voltage (U), alternating current (I), frequency (F), active power (P), reactive power (Q), power factor (PF) etc;

APPLICATION

■ Power plant;

■ Electrical industrial field;

■ Power transformer factory;

■ Metrological service center;

■ Protection relay commission in substation;

■ Electricity power bureau & power company;

■ Power engineering commissioning company;

■ Electrical Department of industrial and mining enterprises; 



Friday, September 13, 2024

T-203 AUTOMATIC THREE PHASE TRANSFORMER TURNS RATIO TESTER

In power transformer Finished product production process, before the new installation of the transformer in operation, according to the national ministry of preventive test procedures, require the operation of transformer turn ratio or voltage ratio test, to check the correctness of the transformer turn ratio tap-changer of transformer whether inter turn short circuit transformer whether can run parallel. T-203 automatic transformer turns ratio tester adopts three-phase power supply output voltage, the test speed Instrument to adopt advanced technology for A/D, wide range range; High speed single chip microcomputer as the core digital processor, the test fast; English menu display, comprehensively improve the humanization and intelligent, instrument optional RS232 serial and USB connect with computer on line, to realize the remote control of the instrument and intelligent analysis of the data A three phase transformation ratio test, the test speed quickly, High accuracy and Perfect protection function.

FEATURES

■ Can be a variety of single-phase three-phase transformer and Z type and so on commonly used than wide test range and error calculation;

■ Three-phase power supply test instrument. Can be set up AC160V / 10 v test voltage. Have a larger output current, load ability. High test speed;

■ High low voltage reverse connect protection function, the short circuit of transformer Inter turn short circuit protection function;

■ Automatic conversion, without artificial calculation, to avoid the problems of variable than non integer input, a higher precision;

■ Large screen LCD menu, not to drop the electric clock and date display, memory 100 test data, in order to you at any time to view and print;

■ Instrument with communication interface, data management software is optional USB storage.

APPLICATION

■ Power plant;

■ Universities;

■ Research institutes;

■ Electrical testing center;

■ Voltage transformer factory;

■ Transformer manufacturers;

■ Railway electrical department;

■ ISO17025 Electrical laboratory;

■ Electricity power bureau & power company;

■ Power engineering commissioning company;

■ Electrical Department of industrial and mining enterprises; 




Sunday, September 8, 2024

TEST-630 SIX PHASE MICROCOMPUTER PROTECTION RELAY TESTER

TEST-630 protection relay tester is a relay test equipment which offers all the characteristics and functions needed for protective relay testing, in a manual or automatic mode, designed for using on site or in the laboratory.

TEST-630 relay test kit is a the most advanced six-phase relay test set available for type and field testing of electromechanical and digital protections of any kinds of relay. It have six phase current output and six phase voltage output, with eight pairs of binary input and four pairs of binary output, wide frequency output from 0 to 1050Hz, high precision and high stability. It is a ideal test tool for substation commission, acceptance testing and maintenance testing in smart grid.

TEST ITEM

■ U/I test

■ DC test

■ I-T test

■ Special test

■ Harmonic test

■ State sequence

■ Fault Recurrence

■ Oscillation test

■ Hardware checkout

■ Differential relay

■ Setting group test

■ Metering instrument

■ Distance protection

■ Synchronization test

■ Power direction test

■ Frequency Protection

■ Low Voltage protection

■ Differential protection

■ Zero sequence protection

■ Impedance characteristics

APPLICATION

■ Power plant;

■ Universities;

■ Research institutes;

■ panel manufacturer;

■ Electrical laboratory;

■ Relay manufacturers;

■ Electrical testing center;

■ Electricity power bureau & power company;

■ Power engineering commissioning company;

■ Electrical Department of industrial and mining enterprises;

FEATURES

■ With PC control software optional;

■ Auto test and manual test optional;

■ COMTRADE recording file fault recurrence wave;

■ Eight pairs of binary input, Four pairs of binary output;

■ Six-channel current output, Six-channel voltage output;

■ High precision and good unique linearity of power amplifier;

■ The test report can be easily derived from the USB port to print;

■ Integration in 8 inches TFT color LCD, light weight and easy to carry;

■ Panel embedded user-friendly buttons, and external keyboard and mouse;

■ High-precision DAC to 12 channel, simultaneously voltage and current output;

■ The newly designed software interface is fully consistent with the host machine operation;

■ Overcurrent, overvoltage, overload, short circuit and over-high temperature intelligent self-protection;

■ It can easily complete the protective device test of ABB, Siemens, Schneider, AREVA and other manufacturers;

■ Built-in high-speed and high-performance industrial computer embedded operating system, running stable and reliable, also can test;

■ Extensive testing capabilities: state sequence, IT features analog oscillation,setting group of test, differential protection test, harmonic test, distance protection test, fault playback, special tests etc.




Thursday, September 5, 2024

GF112B smart single phase energy meter error test equipment

GF112B Single Phase kWh Meter Calibrator is suitable to test various types single phase kWh meters error on site and also can be used to test alternating current parameters - U, I, P, Q, S ,F, E etc. 120A/300V/45-65Hz/0-360.0/0.2%, 2.8inch TFT touch LCD, Unique pincer shaped integrated structure design, application for Electricity power bureau Metrology and testing department. 



 

Sunday, September 1, 2024

GF112 HANDHELD SINGLE PHASE WATT-HOUR METER TESTER

GF112 handheld single phase watt-hour meter tester is with human oriented design, hand-held and lightweight. It is suit for electric power departments, measuring and quality examining departments and electric lab to field use. It is capable of testing various types single phase watt-hour meters on site and can also be used for testing alternating current parameters , for example U, I, P, Q, S, F, E etc.

FEATURES

■ With built-in 5VA load;

■ Energy accumulation check function;

■ Equip with RS232 to connect with PC;

■ With smart optical sampler for energy pulse;

■ Large capacity storage device for mass memory;

■ With 2pcs clamp CT to test ratio of current transformer (Optional);

■ Field test kinds of inductive, electronic single phase watt-hour meter;

■ LCD backlight display, English menu, direct viewing and convenient;

■ Measurement error, voltage, current, power, power factor and frequency at site;

APPLICATION

■ Metrological service center;

■ Power engineering company;

■ Distribution power corporation;

■ Electricity power bureau & power company;

■ National Metrology and testing department;

■ Electrical Department of property company;

■ Electricity meter quality supervision department;

■ Electrical Department of industrial and mining enterprises;